Ultrasonic Detection Analyzers

Equipment produces unique sound patterns within specific sonic and ultrasonic frequency ranges that change as equipment condition deteriorates. By identifying these patterns, typical faults can be identified in mechanical, electrical, and process equipment. Typical faults include:

  • Bearing Lubrication and Mechanical Failure – 75% of bearing faults are lubricant-related
  • Steam Trap and Valve Malfunction – a single ¼” orifice blowing trap costs $6300 per year
  • Air and Steam Leaks – Eliminate losses typical of $75,000 per year
  • Electrical Discharge – Eliminate safety hazards and early electrical failures
  • Vessel Integrity – Quickly find boiler and condenser leaks.





CSI 7100 Machinery Health Scanner – A Simple Point-and-Shoot Solution for Expanding Your PdM Program

The CSI 7100 delivers the audio signal created by defective or malfunctioning equipment and indicates the level of problem severity for the detected fault.

 